Touch or No-touch

Type 10 flush plate

116.025.SN.1

Price $858.00


Features & Specifications

  • Stainless steel - Brushed stainless steel finish
  • AC powered, infrared-controlled flushing for hands-free operation in hygienic or ADA compliant applications
  • For concealed installation in new construction, or retrofit to pre-installed Geberit urinal element 111.625 with front actuation
  • Proven infrared triangulation detection method with background fade-out and auto-calibration to environment
  • Latching solenoid valve with chloramine resistant EPDM diaphragm and protected by dual-stage filters
  • Vandal resistant stainless steel cover plate, with securing bar and independent sensor electronics to prevent tampering
  • Power failure protection (ensure valve closes in the event of power failure during open cycle)
  • Tool-free maintenance, with access to power supply and flush valve behind the actuator plate
  • Detection distance: 4 - 20 in (10 - 50 cm)
  • Dynamic flushing time reduction during periods of high traffic to reduce water consumption
  • Automatic hygiene flush: 24 h after last flush cycle
  • User detection time: 7 s
  • Operating voltage: 110-240V AC, 50-60Hz / Power input < 0.5 W
  • For low consumption urinal flushing volumes to 0.5 GPF (2 LPF)
  • Flow rate at 15 psi (1 bar): 3.8 / 4.7 gpm without flow limiter (0.24 / 0.3 l/s)
  • Flushing time: 3 - 15 s (default time 4 s); can be manually adjusted
  • Humidity <100% (relative)
  • Operating pressure range: 14 - 116 psi (1 - 8 bar)
  • Max. fluid temp: 86°F (30°C)
  • Includes cover plate with replaceable infrared window and securing bar, infrared control pre-mounted on frame, solenoid valve, fastening material, CLASS 2 power supply
  • Note: Not for use with 111.630, 111.650, 111.679, or 111.685 urinal elements

Additional information:

More about installation and configuration